Review





Similar Products

90
Carl Zeiss microscope-integrated ioct zeiss rescan 700
Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations
Microscope Integrated Ioct Zeiss Rescan 700, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc11717337-44-12-20
Average 90 stars, based on 1 article reviews
microscope-integrated ioct zeiss rescan 700 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss microscope-integrated intraoperative oct (ioct machine) rescan 700 microscope-mounted oct system
Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations
Microscope Integrated Intraoperative Oct (Ioct Machine) Rescan 700 Microscope Mounted Oct System, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc09426191-65-11-21
Average 90 stars, based on 1 article reviews
microscope-integrated intraoperative oct (ioct machine) rescan 700 microscope-mounted oct system - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss microscope-integrated ioct opmi lumera 700
Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations
Microscope Integrated Ioct Opmi Lumera 700, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc08978779-47-1-6
Average 90 stars, based on 1 article reviews
microscope-integrated ioct opmi lumera 700 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss lumera 700 with integrated rescan 700 ioct system
Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations
Lumera 700 With Integrated Rescan 700 Ioct System, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc09045909-235-28-27
Average 90 stars, based on 1 article reviews
lumera 700 with integrated rescan 700 ioct system - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss ioct integrated into a surgical microscope rescan 700
Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations
Ioct Integrated Into A Surgical Microscope Rescan 700, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc08947300-113-7-10
Average 90 stars, based on 1 article reviews
ioct integrated into a surgical microscope rescan 700 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss integrated microscope with ioct rescan 700
Clinical Characteristics in Varied Morphological Characteristics of Posterior Lens Opacity.
Integrated Microscope With Ioct Rescan 700, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc08865201-30-2-11
Average 90 stars, based on 1 article reviews
integrated microscope with ioct rescan 700 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss microscope-integrated ioct carl zeiss meditec
Intraoperative OCT-Guided Management of <t>Post-LASIK</t> <t>Epithelial</t> Ingrowth. (a). <t>iOCT-assisted</t> intraoperative delineation of the LASIK flap and the extent of epithelial ingrowth. (b). Dimple-down maneuver to highlight the LASIK flap edge. (c). Flap lifter used to lift a localized area of LASIK flap overlying the ingrowth. iOCT helps to confirm the correct plane of dissection. (d). Epithelial cell nest on the underside of the flap (yellow arrow) and interface (red arrow) visualized on iOCT. (e). Epithelial cell nests scraped off with a blunt dissector, followed by application of ethyl alcohol and MMC 0.02%. (f). Complete removal of epithelial cell nests confirmed on iOCT. (g). Interface space observed on iOCT after repositioning the flap, necessitating further corneal massage. (h). Complete flap apposition confirmed at end of surgery on iOCT. (i). Bandage contact lens applied
Microscope Integrated Ioct Carl Zeiss Meditec, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/microscope+surgical/pmc08917524-5-6-7
Average 90 stars, based on 1 article reviews
microscope-integrated ioct carl zeiss meditec - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss integrated microscope with ioct opmi lumera 700
Intraoperative OCT-Guided Management of <t>Post-LASIK</t> <t>Epithelial</t> Ingrowth. (a). <t>iOCT-assisted</t> intraoperative delineation of the LASIK flap and the extent of epithelial ingrowth. (b). Dimple-down maneuver to highlight the LASIK flap edge. (c). Flap lifter used to lift a localized area of LASIK flap overlying the ingrowth. iOCT helps to confirm the correct plane of dissection. (d). Epithelial cell nest on the underside of the flap (yellow arrow) and interface (red arrow) visualized on iOCT. (e). Epithelial cell nests scraped off with a blunt dissector, followed by application of ethyl alcohol and MMC 0.02%. (f). Complete removal of epithelial cell nests confirmed on iOCT. (g). Interface space observed on iOCT after repositioning the flap, necessitating further corneal massage. (h). Complete flap apposition confirmed at end of surgery on iOCT. (i). Bandage contact lens applied
Integrated Microscope With Ioct Opmi Lumera 700, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pm32618830-42-0-10
Average 90 stars, based on 1 article reviews
integrated microscope with ioct opmi lumera 700 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss lumera 700 zeiss ophthalmic microscope with integrated rescan 700 ioct engine
Intraoperative OCT-Guided Management of <t>Post-LASIK</t> <t>Epithelial</t> Ingrowth. (a). <t>iOCT-assisted</t> intraoperative delineation of the LASIK flap and the extent of epithelial ingrowth. (b). Dimple-down maneuver to highlight the LASIK flap edge. (c). Flap lifter used to lift a localized area of LASIK flap overlying the ingrowth. iOCT helps to confirm the correct plane of dissection. (d). Epithelial cell nest on the underside of the flap (yellow arrow) and interface (red arrow) visualized on iOCT. (e). Epithelial cell nests scraped off with a blunt dissector, followed by application of ethyl alcohol and MMC 0.02%. (f). Complete removal of epithelial cell nests confirmed on iOCT. (g). Interface space observed on iOCT after repositioning the flap, necessitating further corneal massage. (h). Complete flap apposition confirmed at end of surgery on iOCT. (i). Bandage contact lens applied
Lumera 700 Zeiss Ophthalmic Microscope With Integrated Rescan 700 Ioct Engine, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/integrated+ioct/700+confocal+lsm+microscope/pmc07901333-558-15-19
Average 90 stars, based on 1 article reviews
lumera 700 zeiss ophthalmic microscope with integrated rescan 700 ioct engine - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations

Journal: Taiwan Journal of Ophthalmology

Article Title: Advances in intraoperative imaging in retinal diseases: A narrative review

doi: 10.4103/tjo.TJO-D-24-00078

Figure Lengend Snippet: Comparison of the main intraoperative optical coherence tomography machines currently available on the market, highlighting their technical characteristics, advantages, and limitations

Article Snippet: [ ] The DISCOVER study evaluates the feasibility and utility of microscope-integrated iOCT during ophthalmic surgery over 3 years using Zeiss Rescan 700, Leica Enfocus, and Cole Eye iOCT system.

Techniques: Comparison, Tomography, Imaging, Microscopy, Control

Clinical Characteristics in Varied Morphological Characteristics of Posterior Lens Opacity.

Journal: Journal of Cataract and Refractive Surgery

Article Title: Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery

doi: 10.1097/j.jcrs.0000000000000763

Figure Lengend Snippet: Clinical Characteristics in Varied Morphological Characteristics of Posterior Lens Opacity.

Article Snippet: An integrated microscope with iOCT (OPMI Lumera 700 and RESCAN 700; Carl Zeiss Meditec AG) was used to assess the morphology of lens opacity and the posterior capsular status just after general anesthesia with tracheal intubation during surgery.

Techniques: Polymerase Chain Reaction

Morphological variants of type I posterior lens opacity observed on iOCT. A : Type Ia characterized by the PC was clearly identified in the entire lens opacity. B : Type Ib characterized by the PC could not be clearly delineated in the areas of dense opacities that apparently adhered to the PC. C : Type Ic characterized by the PC was apparently thickened as highly reflective dense opacities adherent tightly to the PC. iOCT = intraoperative OCT; PC = posterior capsule

Journal: Journal of Cataract and Refractive Surgery

Article Title: Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery

doi: 10.1097/j.jcrs.0000000000000763

Figure Lengend Snippet: Morphological variants of type I posterior lens opacity observed on iOCT. A : Type Ia characterized by the PC was clearly identified in the entire lens opacity. B : Type Ib characterized by the PC could not be clearly delineated in the areas of dense opacities that apparently adhered to the PC. C : Type Ic characterized by the PC was apparently thickened as highly reflective dense opacities adherent tightly to the PC. iOCT = intraoperative OCT; PC = posterior capsule

Article Snippet: An integrated microscope with iOCT (OPMI Lumera 700 and RESCAN 700; Carl Zeiss Meditec AG) was used to assess the morphology of lens opacity and the posterior capsular status just after general anesthesia with tracheal intubation during surgery.

Techniques:

Morphological variants of type II posterior lens opacity observed on iOCT. Type II characterized by the PC and the cortex bulged along the anterior vitreous, showing a V shape ( A , B ) or a U shape ( C ). iOCT = intraoperative OCT; PC = posterior capsule

Journal: Journal of Cataract and Refractive Surgery

Article Title: Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery

doi: 10.1097/j.jcrs.0000000000000763

Figure Lengend Snippet: Morphological variants of type II posterior lens opacity observed on iOCT. Type II characterized by the PC and the cortex bulged along the anterior vitreous, showing a V shape ( A , B ) or a U shape ( C ). iOCT = intraoperative OCT; PC = posterior capsule

Article Snippet: An integrated microscope with iOCT (OPMI Lumera 700 and RESCAN 700; Carl Zeiss Meditec AG) was used to assess the morphology of lens opacity and the posterior capsular status just after general anesthesia with tracheal intubation during surgery.

Techniques:

Morphological variants of type III (deficient PC) observed on iOCT. A and B : The posterior opacity showed a morphology of the moth-eaten appearance of the edge of the leaves in 2 cases. C : The PC in the third case was deficient beneath the bulged lens opacities. Intact PC was visible in periphery of the opacity ( white arrow ) while deficient in the center of opacity ( red arrow ). iOCT = intraoperative OCT; PC = posterior capsule

Journal: Journal of Cataract and Refractive Surgery

Article Title: Intraoperative OCT for the assessment of posterior capsular integrity in pediatric cataract surgery

doi: 10.1097/j.jcrs.0000000000000763

Figure Lengend Snippet: Morphological variants of type III (deficient PC) observed on iOCT. A and B : The posterior opacity showed a morphology of the moth-eaten appearance of the edge of the leaves in 2 cases. C : The PC in the third case was deficient beneath the bulged lens opacities. Intact PC was visible in periphery of the opacity ( white arrow ) while deficient in the center of opacity ( red arrow ). iOCT = intraoperative OCT; PC = posterior capsule

Article Snippet: An integrated microscope with iOCT (OPMI Lumera 700 and RESCAN 700; Carl Zeiss Meditec AG) was used to assess the morphology of lens opacity and the posterior capsular status just after general anesthesia with tracheal intubation during surgery.

Techniques:

Intraoperative OCT-Guided Management of Post-LASIK Epithelial Ingrowth. (a). iOCT-assisted intraoperative delineation of the LASIK flap and the extent of epithelial ingrowth. (b). Dimple-down maneuver to highlight the LASIK flap edge. (c). Flap lifter used to lift a localized area of LASIK flap overlying the ingrowth. iOCT helps to confirm the correct plane of dissection. (d). Epithelial cell nest on the underside of the flap (yellow arrow) and interface (red arrow) visualized on iOCT. (e). Epithelial cell nests scraped off with a blunt dissector, followed by application of ethyl alcohol and MMC 0.02%. (f). Complete removal of epithelial cell nests confirmed on iOCT. (g). Interface space observed on iOCT after repositioning the flap, necessitating further corneal massage. (h). Complete flap apposition confirmed at end of surgery on iOCT. (i). Bandage contact lens applied

Journal: Indian Journal of Ophthalmology

Article Title: Intraoperative optical coherence tomography-guided management of postlaser-assisted in situ keratomileusis epithelial ingrowth

doi: 10.4103/ijo.IJO_1173_21

Figure Lengend Snippet: Intraoperative OCT-Guided Management of Post-LASIK Epithelial Ingrowth. (a). iOCT-assisted intraoperative delineation of the LASIK flap and the extent of epithelial ingrowth. (b). Dimple-down maneuver to highlight the LASIK flap edge. (c). Flap lifter used to lift a localized area of LASIK flap overlying the ingrowth. iOCT helps to confirm the correct plane of dissection. (d). Epithelial cell nest on the underside of the flap (yellow arrow) and interface (red arrow) visualized on iOCT. (e). Epithelial cell nests scraped off with a blunt dissector, followed by application of ethyl alcohol and MMC 0.02%. (f). Complete removal of epithelial cell nests confirmed on iOCT. (g). Interface space observed on iOCT after repositioning the flap, necessitating further corneal massage. (h). Complete flap apposition confirmed at end of surgery on iOCT. (i). Bandage contact lens applied

Article Snippet: We performed our technique of microscope-integrated iOCT [Zeiss RESCAN 700, Carl Zeiss Meditec, Germany]-guided removal of the epithelial ingrowth in cases with significant epithelial ingrowth involving the visual axis.

Techniques: Dissection

A case of post-LASIK Epithelial Ingrowth managed with iOCT guided removal. (a). Preoperative Slit-lamp image showing interface epithelial cell nests encroaching the visual axis at 5–6’o clock. (b). Preoperative ASOCT showing LASIK flap with epithelial cell nests in the interface. (c). Postoperative 1-month slit-lamp photograph showing minimal fibrosis at the underside of the LASIK flap with a clear interface and underlying stroma. (d). Postoperative ASOCT showing no residual epithelial cell nests

Journal: Indian Journal of Ophthalmology

Article Title: Intraoperative optical coherence tomography-guided management of postlaser-assisted in situ keratomileusis epithelial ingrowth

doi: 10.4103/ijo.IJO_1173_21

Figure Lengend Snippet: A case of post-LASIK Epithelial Ingrowth managed with iOCT guided removal. (a). Preoperative Slit-lamp image showing interface epithelial cell nests encroaching the visual axis at 5–6’o clock. (b). Preoperative ASOCT showing LASIK flap with epithelial cell nests in the interface. (c). Postoperative 1-month slit-lamp photograph showing minimal fibrosis at the underside of the LASIK flap with a clear interface and underlying stroma. (d). Postoperative ASOCT showing no residual epithelial cell nests

Article Snippet: We performed our technique of microscope-integrated iOCT [Zeiss RESCAN 700, Carl Zeiss Meditec, Germany]-guided removal of the epithelial ingrowth in cases with significant epithelial ingrowth involving the visual axis.

Techniques: